[ad_1]

  1. Determine the reference design value of the single 7/8 in full-diameter body A307 bolt shown. The load in the
    connection is parallel to grain in the 6 x wood member, and ΒΌ in-thick steel side plates. The wood member is
    Douglas Fir larch and the side plates are steel with Fu of 58 ksi. Fes=1.5*Fu

2.The horizontal load in the connection shown is parallel to grain in the horizontal member and perpendicular to
the grain in the vertical member. Lumber is Douglas Fir Larch. Determine the reference design value of the
single 16d common nail.

Sample Solution

The post Wood Member Load in Connection appeared first on acestar tutors.